Specifications
|
Chassis |
|
|
Input AC Power |
115 VAC @ 8A, 50/60 Hz, or 230 VAC @ 5 A, 50/60 Hz Autorange switching |
|
Total Available DC Power |
400 W |
|
+5V +3.3V +12V -12V |
50 A (Max) 30 A (Max) 27A (Max) 3 A (Max) |
|
Weight GX7600 GX7610 |
16 lbs 13 lbs |
|
|
Dimensions GX7600, GX7610 |
4U (7”) H x 8.9” W x 18” D |
|
Cooling |
Two 65CFM fans for system cooling. Dedicated fan for power supply cooling. |
|
Temperature |
|
Integrated temperature monitoring via an on-board microcontroller with audible and software notification when preset temperature limits are exceeded. Per slot temperature monitoring, 1 reading/sec/slot 4 second moving average value User selectable alarm criteria: •Maximum slot temperature •Average slot temperature Accuracy: +/- 2 ° C Default warning and shutdown limits: +50 ° C & +70° C Warning and shutdown limits programmable via software driver Status: Query via software driver and audible alarm for a warning limit condition | |
|
Power Supply Monitoring |
Monitored voltages: +3.3, +5, +12, -12, VIO value Accuracy: +/- 2% of reading |
|
PXI Triggers |
Slots: 2-9 Number: 8 |
|
PXI Star Triggers |
|
Slots: 2-9 Dedicated, low skew Star trigger connecting slots 2, 3, and 5-9 to slot 4, the PXIe system timing slot | |
|
Environmental Temperature Range
|
Operating: |
0° C to 50° C |
|
|
CE Compliance |
EN55011 Class A EN61326 |
|
|
|
|
|
|
|
Descripcion
Geotest GX7600 PXI Bus 9-Slot 3U PXI Express Smart Chassis Features
The GX7600 Series mainframes are compact, 9-slot PXI chassis that can accommodate up to 8 instruments as well as an embedded single slot PXI Express controller such as the GX7940 or a PXI Express external bus controller such as the x1 or x4 MXI - PXI Express interface. The GX7600’s compact 3U form-factor occupies only 9x18 inches of bench space, making it ideal for benchtop or space constrained applications. And when combined with 8 peripheral slots, integral Smart functions, and the bandwidth of PXI Express, the GX7600 represents a new level of performance, capabilities and value for PXI mainframes.
Applications
|
|
Automatic Test Equipment (ATE) |
|
Data Acquisition |
|
Process Control |
|
Production Test |
|
Research and Development |
|
Scientific Applications |
|
Industrial Systems |
Configuration
The nine-slot layout of the GX7600 consists of five PXI slots, two PXI hybrid slots, one PXIe timing slot, and one cPCIe controller slot. The PXI backplane supports a x4 PCI Express lane configuration for the two hybrid slots and the system timing slot, providing an aggregate bus bandwidth of 3 GB/s. An additional x1 PCI Express lane interfaces to a PCI bridge device for support of the 5 PXI slots. Full support of the PXI Express timing, triggering, and synchronization resources is provided including support for the PXI Express system timing slot
|
|
|
|
|
|
|
|
|