AC WITHSTANDING Output-Voltage Range 0.100kV~5.000kV ac Output-Voltage Resolution 2V/step Output-Voltage Accuracy } (1% of setting + 5V) [no load] Maximum Rated Load 500 VA (5kV/100mA) Maximum Rated Current 100mA (0.5kV< V …5kV) 10mA (0.1kV… V …0.5kV) Output-Voltage Waveform Sine wave Output-Voltage Frequency 50 Hz / 60 Hz selectable Voltage Regulation } (1% of reading + 5V) [full load ¨ no load] Voltmeter Accuracy } (1% of reading + 5V) Current Measurement Range 0.001mA~100.0mA Current Best Resolution 0.001mA / 0.01mA /0.1mA Current Measurement Accuracy }(1.5% of reading + 30 counts) when HI SET < 1.11mA }(1.5% of reading + 3 counts) when HI SET †1.11mA Window Comparator Method Yes ARC Detect Yes Sweep Function* Yes RAMP (Ramp-Up Time) 0.1s~999.9s TIMER (Test Time)* OFF, 0.5s~999.9s GND ON/OFF DC WITHSTANDING Output-Voltage Range 0.100kV~6.000kV dc Output-Voltage Resolution 2V/step Output-Voltage Accuracy } (1% of setting + 5V) [no load] Maximum Rated Load 100W (5kV/20mA) Maximum Rated Current 20mA (0.5kV< V …6kV) 2mA (0.1kV… V …0.5kV) Voltage Regulation } (1% of reading + 5V) [full load ¨ no load] Voltmeter Accuracy } (1% of reading + 5V) Current Measurement Range 0.001mA~20.0mA Current Best Resolution 0.001mA /0.01mA /0.1mA Current Measurement Accuracy }(1.5% of reading + 30 counts) when HI SET < 1.11mA }(1.5% of reading + 3 counts) when HI SET †1.11mA Window Comparator Method Yes ARC Detect Yes Sweep Function* Yes RAMP (Ramp-Up Time) 0.1s~999.9s TIMER (Test Time)* OFF, 0.5s~999.9s GND ON/OFF INSULATION RESISTANCE Output Voltage 50V~1000V dc Output-Voltage Resolution 50V/step Output-Voltage Accuracy } (1% of setting + 5V) [no load] Resistance Measurement Range 0.001Gƒ¶~ 50.00Gƒ¶ Test Voltage & Measurement Accuracy 50V…V …450V 0.001~0.050Gƒ¶F}(5% of reading + 1 count) 0.051~2.000Gƒ¶F}(10% of reading + 1 count) 500V… V …1000V 0.001~0.500Gƒ¶F}(5% of reading + 1 count) 0.501~9.999Gƒ¶F}(10% of reading + 1 count) 10.00~50.00Gƒ¶F}(15% of reading + 1 count) Output Impedance 600kƒ¶ Window Comparator Method Yes Sweep Function* Yes RAMP (Ramp-Up Time) 0.1s~999.9s TIMER (Test Time) 1s~999.9s GND OFF (fixed) Ground Bond (GPT-9904 only) Output-Current 03.00A~32.00A ac Output-Current Resolution 0.01A Output-Current Accuracy 3A…I…8AF}(1% of reading + 0.2A) 8A<I…32AF}(1% of reading + 0.05A) Test-Voltage 6Vac max (open circuit) Test-Voltage Frequency 50Hz/60Hz selectable Resistance Measurement Range 10.0mƒ¶~ 650.0mƒ¶ Resistance Measurement Resolution 0.1mƒ¶ Resistance Measurement Accuracy }(1% of reading + 2 mƒ¶) Window Comparator Method Yes Sweep Function* Yes TIMER (Test Time) 0.5s~999.9s Test Method Four Terminal GND OFF (fixed) MEMORY Single Step Memory MANUF100 blocks Automatic Testing Memory AUTOF100 blocks, manu per autoF16 INTERFACE Rear Output Standard RS-232C Standard USB Standard GPIB Option Remote terminal (Front) Standard Signal I/O Standard DISPLAY 240 x 64 Ice Blue Dot matrix LCD POWER SOURCE AC 100V/120V/220V/230V } 10%, 50/60Hz DIMENSION & WEIGHT 330(W) x 148(H) x 587(D) mm Approx. 27kg max. for GPT-9904/9903 |
Reseñas