Hioki 3258
| Measurement Object | Covered electric conductors (minimum 100 mm2), Metallic terminals Note: cannot measure shielded electric wires |
| AC Voltage 40 to 66 Hz | 30.0V to 420.0V, 380V to 600V, 2 ranges (Basic accuracy: ±1.5% rdg. ±5 dgt. /true RMS rectified, band width 40Hz to 400Hz at 420.0V range) |
| Crest Factor | 1.8 (only sine wave at 600V range) |
| Maximum Rated Voltage to Earth | 600V AC rms |
| Functions | Data hold function, auto-power save, low battery alarm |
| Display | Digital LCD, max. 4200 digit, zero suppress at 10 digits or less |
| Sampling Rate | 1.67 times/sec (approx. 600 msec period) |
| Response Time: 2.4 sec or less | |
| Power Consumption | Six AA alkaline (LR6) batteries |
| Continuous use: 14 hours (Power ON, no measurement), or 1-minute measurements for 1000 times, or 5-minute measurements for 200 times | |
| Dimensions, Mass | Width: 51mm (2.01in) Height: 275mm (10.83in) Diameter: 37.5mm (1.48in) |
| One Probe: 670g (23.6oz) |