Navigate to the Final Test homepage

Embarcamos a cualquier
lugar del mundo!

Sorensen SGA 50-300,

Sorensen SGA 40-375

Sorensen SGA 50-300 - Fuente de Poder Programable de DC. 15kW, 50V, 300A.

Ametek
$
Codigo del Producto: SGA-50X300
8 a 10 semanas
  • High Power Density: Up to 15 kW in a 3U / 30 kW in a 6U chassis
  • Wide Voltage Range: 0-40V up to 0-600V, in increments of 5 kW from 5 to 30 kW
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise: Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection
  • Sequencing: Program custom waveforms
  • Easy-to-read Fluorescent Display: SGI supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
  • 16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Ethernet Control: LXI Class C compliant communication through integrated web server
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
  • Hardware Trigger: Ethernet Option Only
  • 5 Year Warranty

    Applications

    Process Control
    Whether you are controlling ion beams for the manufacturer of semiconductors, or driving a solution for precise control in a plating process, the SG series is an ideal choice with it’s small size, reliable modular design and standard analog programmability. Direct control of V and I along with 0-10V outputs allowing monitoring of the actual voltage and current, provides a simple interface for your PLC or other type of analog controller.

    Product Development
    Testing & Burn-in DC-DC converters, laser diodes, automotive and semiconductor components and aircraft flight hardware are just a few of the items being tested using the SG product family. From simple front panel control to complex test sequences for compliance testing, the SG series will grow with your product needs.

    Research
    A research environment presents some of the most demanding requirements on your test instrumentation. Equipment that is sufficient today, may not meet the needs of the next project. With the SG series this is no longer a problem. The modular design allows you to easily upgrade to higher power levels in the future, or parallel units to achieve up to 150 kW. With the sophisticated sequencing capability of the SGI model, you can build an infinite variety of test or diagnostic programs and have them execute directly from the power supply.

    Automotive Component Test
    The 16-bit resolution of the Ethernet programming and hardware triggering allows for detailed sequencing associated with battery fluctuation simulation. The tight load regulation capability of the SG series makes it a superior source for validation and acceptance testing and burn-in of automotive components. The 40V models, in particular, provide a full range of testing to simulate battery conditions. Margin testing of 12V and 14V nominal components, such as electronic control units (ECU) and electromechanical components, is easily achieved.

    Rackmount ATE Systems
    The high power density of the SG series makes it ideal for ATE System integration. The wide variety of voltage and current combinations in 3U and 6U heights allows multiple voltage outputs in a small amount of space. The wide variety of control methods possible, allows easy integration into legacy systems as well as high speed systems.

    Battery Charging
    The SG series provides high accuracy voltage output to optimize battery charging. Battery charging requires high accuracy voltage and stable current output for fast bulk and absorption phase charging and high accuracy and stable voltage for float charging to avoid “gassing” the battery. With the remote interface options, the charging process can easily be automated for volume production.

    The SG series represents the next generation of high power programmable DC power supplies. Designed for exceptional load transient response, low noise and the highest power density in the industry. The industry leading power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.

    At the heart of the SG series is a 5 kW modular supply. Depending on the output voltage, one to six modules can be configured in a single chassis to deliver 5 kW to 30 kW of power. These chassis can then be easily paralleled to achieve power levels up to 150 kW. Paralleled units operate like one single supply providing total system current. Available in two control versions, the SGA has basic analog controls, while the SGI provides intelligent control features
    LXI CompliantNow with LXI Compliant Ethernet Communication.

    SGI: Advanced Intelligent Control
    (Sorensen General purpose Intelligent) The SGI combines onboard intelligent controls with the outstanding power electronics common to all SG family supplies. These controls enable sophisticated sequencing, constant power mode and save/recall of common setups, making the SGI ideal for repetitive testing using complex or compliance waveforms. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI.

    SGA: Outstanding Value - Analog Control
    (Sorensen General purpose Analog) The SGA, with its industry leading price performance, is available for customers requiring simple front panel analog controls or external control. With the same high performance power electronics as the SGI, the SGA provides essential features like 10- turn potentiometers for setting voltage and current, 3 ½ digit LED readout plus front panel OVP preview/adjustment and reset.

    SGI / SGA Comparison Chart
    FeatureSGASGI
    Modular Design
    Fast Load Transient
    Parallelable
    Analog & Digital Summing Optional
    Direct Front Panel V/1 Control
    3½ Digit LED Readout
    Graphics Display
    Sequencing
    Save / Recall Setups
    System Power Readouts
    Constant Power Mode
    IEEE-488.2/RS-232CRS-232C Std
    IEEE-488.2 Optional
    LXI Compliant Ethernet OptionalOptional
    Applications
    Burn-InCompliance Testing
    Materials ResearchProcess control
    Product ValidationAutomotive Electronics
    Rackmount ATE SystemsBattery Charging
  • Common
    Remote SenseLoad-line loss compensation for models <= 100V is 10% above full scale voltage total (5% per load-line), and models > 100V is 4% above full scale voltage total (2% per load-line).
    Parallel OperationUp to 5 units may be paralleled for additional current within the power supply single-unit specifications, with exception of the DC output current set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory.
    Series OperationUp to 2 units (See Output Float Voltage)
    Input
    Nominal Voltage 3 phase, 3 wire + ground208/220 VAC (operating range 187 - 242VAC) 380/400 VAC (operating range 342 - 440VAC) 440/480 VAC (operating range 396 - 528VAC)* *Optional
    Frequency47 – 63Hz
    Power Factor>0.9 typical at 208/220 VAC input
    >0.78 typical at 380/400 VAC input
    >0.69 typical at 440/480 VAC input
    Protection½ cycle ride-though on all three phases, 3 cycle ride-through on single phase; missing phase shutdown
    Input: AC Voltage and Current
    Output PowerMax AC Input Current (A) per Phase, Low Line
    187-242 VAC342-440 VAC396-528 VAC
    5kW (3U)211413
    10kW (3U)412726
    15kW (3U)624039
    20kW (6U)835452
    25kW (6U)1036765
    30kW (6U)1248078
    Output: Voltage and Current Ranges
    3U6URipple & Noise
    Power5
    kW
    10
    kW
    15
    kW
    20
    kW
    25
    kW
    30
    kW
    rms (20Hz-300kHz)p-p
    VoltageCurrent
    40125250375500*625*750*20mV75mV
    608316725033341750020mV75mV
    806312518825031337520mV100mV
    1005010015020025030020mV100mV
    16031639412515618825mV150mV
    20025507510012515025mV175mV
    2502040608010012030mV200mV
    33015304561769130mV200mV
    40012253850637530mV300mV
    6008172533425060mV350mV
    * By way of paralleling 5kW, 10kW & 15kW supplies
    Output
    Ripple & Noise
    (Voltage Mode)
    See Output: Voltage & Current Ranges Chart Above. Ripple and noise specified at full load, nominal AC input
    Ripple (Current Mode)<+/- 0.04% of full scale rms current
    DC Voltage Slew Rate100 msec 5-95% of full scale typical (Contact factory for model specific slew rates)
    DC Current Slew Rate45A / ms typical
    Line Regulation(±10% of nominal AC input, constant load)
    Voltage Mode: +/- 0.01% of full scale
    Current Mode: +/- 0.05% of full scale
    Load Regulation(no load to full load, nominal AC input)
    Voltage Mode: +/- 0.02% of full scale
    Current Mode: +/- 0.1% of full scale
    Load Transient ResponseRecovers within 1ms to +/-0.75% of steadystate output for a 50% to 100% or 100% to 50% load change
    Efficiency87% typical at nominal line and max load
    Stability±0.05% of set point after 8 hrs. warm-up at fixed line, load
    and temperature
    Temperature Coefficient0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output current rating for current set point
    Output Float VoltageNegative terminal within +/- 150 V of chassis potential
    Physical
    DimensionsWidth:
    19.00” (48.3 cm), Depth 25.0” (63.5 cm)
    Height:
    5-15 kW Units: 3U – 5.25”
    rack mount (13.34 cm)
    20-30 kW units: 6U – 10.5”
    rack mount (26.67 cm)
    Weight & Shipping Weight
    Weight3U, 5kW ~ 40 lbs (18kg)
    3U, 10kW ~ 60 lbs (27kg)
    3U, 15kW ~ 80 lbs (36kg)
    6U, 20kW ~ 120 lbs (54kg)
    6U, 25kW ~ 140 lbs (63kg)
    6U, 30kW ~ 160 lbs (72kg)
    Shipping Weight3U, 5kW ~ 70 lbs (32kg)
    3U, 10kW ~ 90 lbs (41kg)
    3U, 15kW ~ 110 lbs (50kg)
    6U, 20kW ~ 150 lbs (68kg)
    6U, 25kW ~ 170 lbs (77kg)
    6U, 30kW ~ 190 lbs (86kg)
    Programming & Read-back Specifications
    ProgrammingRead-Back / Monitoring
    AccuracyResolutionAccuracyResolution
    Front panel DisplaySGA: +/- (0.5%fs + 1 digit) SGI, Voltage: +/- 0.1% of full scale SGI, Current: +/- 0.4% of full scaleSGA: 3.5 digits SGI: 4.0 digitsSGA: +/- (0.5%fs + 1 digit) SGI, Voltage: +/- 0.1% of full scale SGI, Current: +/- 0.4% of full scaleSGA: 3.5 digits SGI: 4.0 digitsKnob control & Display read-back
    Remote Analog InterfaceVoltage: +/-0.25% of full scale for 0-5V range, +/-0.5% of full scale for 0-10V range Current: 0.8% of full scaleNA+/-1.0% of full scale (0 - 10V)NA25-pin D-sub connector (0~5V or 0~10V)
    Remote Digital InterfaceVoltage: +/- 0.1% of full scale, Current: +/- 0.4% of full scale+/-0.002% of full scaleVoltage: +/- 0.15% of full scale, Current: +/- 0.4% of full scale+/-0.002% of full scaleRS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet (see Options)
    OVP+/- 1% of full scale+/-0.002% of full scaleProgramming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
    User I/ODisconnect & Polarity-reversal relay control ( Only available with Ethernet Option )Digital 10-pin Molex type connector Chart Below
    Analog User I/O Pinouts
    1Isolated Remote ON/OFF 14Isolated TTL/CMOS ON/OFF Control
    2Isolated Circuit Return 15Remote Voltage Programming
    3Remote Overvoltage Set 16Remote Current Programming
    4Voltage Return for Pins 9, 15, or 21 17Fault State
    5Remote ON/OFF 18Shutdown Fault
    6Circuit Common 19Output Voltage Monitor
    7Output Current Monitor 20Voltage Return for Pins 9, 15, or 21
    8Local Voltage Control Monitor21Voltage Control Resistance
    9Remote Voltage Programming 22Current Control Resistance
    10Remote Current Programming 23Current Return for Pins 10, 16, or 22
    11Local Current Control Monitor 24Circuit Common
    1260V Remote Sense 25Current Return for Pins 10, 16, or 22
    Digital User I/O Pinouts ( Ethernet Option Only )
    1Fold Back Monitor
    2Direct Shutdown
    3Fault Indication
    4Trigger Out
    5Common
    6Polarity output reversal signal
    7Isolation relays relay open signal
    8Sense relays open signal
    9Common
    10Trigger in

    Reseñas