Navigate to the Final Test homepage

Embarcamos a cualquier
lugar del mundo!

Amprobe ACDC-100 TRMS

Amprobe ACDC-100 TRMS

Amprobe ACDC-100 TRMS, Pinza de AC/DC Version Verdadero Valor Eficaz

Amprobe
$
Codigo del Producto: ACDC-100-TRMS
4 a 6 Semanas
  • True RMS
  • Backlight
  • Capacitance test
  • AC/DC voltage to 600V
  • Resistance
  • Continuuity Beeper
  • Relative zero mode
  • Auto power off
  • Data hold
  • MAX capture function for in rush current measurements (30 mS response)
  • Large, easy to read digital display
  • Diode Test
  • Audible continuity
  • Accommodates conductors up to 50mm (2.00") in diameter
  • "Third hand" - test probe holder
  • Rubber over-molded case with built-in probes storage
  • Carrying case, test leads, batteries (installed) and user manual included

 

General Specifications
Display3-3/4 digits 4000 counts LCD display
Update Rate3 per second nominal
PolarityAutomatic
Low BatteryBelow approx. 2.4V
Operating Temperature0C to 40C
Relative HumidityMaximum relative humidity 80% for temperature up to 31C decreasing linearly to 50% relative humidity at 40C
AltitudeOperating below 2000m
Storage Temperature-20C to 60C, < 80% R.H. (with battery removed)
Temperature Coefficientnominal 0.15 x (specified accuracy)/ C @(0C -18C or 28C -40C), or otherwise specified
SensingTrue RMS
SafetyMeets EN61010-1:2001; IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003) Category III 600 Volts AC & DC.
Transient protection6.5kV (1.2/50ƒÊs surge) for all models
Pollution degree2
E.M.C.Meets EN61326-1
Overload Protections
Clamp-on jawsDC 1000A or AC 800A rms continuous + & COM terminals (all functions) : 600VDC/VAC rms
Power Supplystandard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2
Power Consumptiontypical 11mA for ACA/DCA and 2.9mA for other functions
APO TimingIdle for 30 minutes
APO Consumptiontypical 190ƒÊA
DimensionL227mm X W78mm X H40mm
Weight290 gm approx
Jaw opening & Conductor diameter50mm max
FunctionRangeAccuracy
Electrical SpecificationsAccuracy is }(% reading digits + number of digits) or otherwise specified, at 23Ž } 5Ž & less than 75% R.H.
DC Voltage
 400.0 mV0.3% + 3d
 4.000V, 40.00V, 400.0V0.5% + 3d
 600V1.0% + 4d
NMRR :>50dB @ 50/60Hz 
CMRR :>120dB @ DC, 50/60Hz, Rs=1kƒ¶ 
Input Impedance :10Mƒ¶, 30pF nominal (1000Mƒ¶ for 400.0mV range) 
AC Voltage
50Hz ~ 500Hz400.0mV 1)4.0% + 4d
50Hz ~ 60Hz4.000V, 40.00V, 400.0V1.0% + 4d
60Hz ~ 500Hz4.000V, 40.00V, 400.0V1.5% + 4d
50Hz ~ 500Hz600V2.0% + 4d
CMRR :>60dB @ DC to 60Hz, Rs=1kƒ¶ 
Input Impedance:10Mƒ¶, 30pF nominal 
ACDC-100 TRMS Crest Factor:< 1.6 : 1 at full scale & < 3.2 : 1 at half scale 
1) Selection by RANGE button manually, and is specified AC 60mV and up
Resistance
 400.0ƒ¶0.8% + 6d
 4.000kƒ¶, 40.00kƒ¶, 400.0kƒ¶0.6% + 4d
 4.000Mƒ¶1.0% + 4d
 40.00Mƒ¶2.0% + 4d
Open Circuit Voltage :0.4VDC typical 
Audible Continuity Tester
Open Circuit Voltage:0.4VDC typical 
Range: 400.0ƒ¶; Accuracy:1.5% + 6d 
Audible threshold:between 10ƒ¶ and 120ƒ¶. 
Diode Tester
Open Circuit VoltageTest Current (Typical) 
< 1.6 VDC0.4mA 
Capacitance
 500.0nF, 5.000ƒÊF, 50.00ƒÊF,
500.0ƒÊF, 3000ƒÊF 1)
3.5% + 6d2)3)
1) Additional 50.00nF range accuracy is not specified
2) Accuracies with film capacitor or better
3) Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery
warning voltage of approximately 2.4V
DC Current (Clamp-on)
400.0A0.0A ~ 400.0A1.5% + 4d 1)2)
1000A400A ~ 800A1.5% + 4d 1)2)
 800A ~ 900A2.0% + 4d 1)2)
 900A ~ 1000A5.0% + 30d 1)2)
1) Induced error from adjacent current-carrying conductor: < 0.01A/A
2) Ģ Zero mode must be applied to zero the unit before measurement to ensure accuracy. This is particularly important below 20A.
AC Current (Clamp-on)
400.0A  
 15Hz ~ 40Hz2.0% + 5d 1)2)3)
 40Hz ~ 200Hz1.5% + 5d 1)2)
 200Hz ~ 400Hz @ <50A 4)1.5% + 5d 1)2)
 400Hz ~ 1kHz @ <50A 4)2.0% + 5d 1)2)
800A  
 15Hz ~ 40Hz @ 400A ~ 600A2.0% + 5d 1)2)3)
 40Hz ~ 100Hz @ 400A ~ 600A1.5% + 4d 1)2)
 15Hz ~ 60Hz @ 600A ~ 800A5.0% + 30d 1)2)
1) Induced error from adjacent current-carrying conductor: < 0.01A/A
2) ACDC-100 TRMS crest Factor: < 1.6 : 1 at full scale & < 3.2 : 1 at half scale
3) 4.0% + 5d for ACDC-100 TRMS
4) Accuracy is specified at <50A in this frequency bandwidth due to limited calibrator output capability for testing