Amprobe ACDC-100

Amprobe ACDC-100

Amprobe ACDC-100 Gancho de AC/DC

Amprobe
$
Codigo del Producto: ACDC-100
1 a 2 Semanas
  • TRMS & Display Backlight (ACDC-100TRMS)
  • Auto & Manual Ranging
  • Relative Zero Mode
  • Auto Power Off
  • Data Hold
  • MAX Capture Function For In Rush Current Measurements (30 mS response)
  • Large, Easy To Read LCD Display
  • Diode Test
  • Audible Continuity
  • Accommodates Conductors Up To 2.00" (50mm) In Diameter
  • "Third Hand" - Test Probe Holder
  • Rubber Over-Molded Case With Built-In Probes Storage
  • Safety: CAT III 600V
FeaturesRangeAccuracy
AC Voltage50Hz - 500Hz400.0 mV 4.0% + 4 digits

Selection by RANGE button manually, and is specified from AC 40mV (AC 60mV for True RMS model ACD-6 TRMS-PRO) and up

50Hz -- 60Hz 4.000V, 40.00V, 400.0V 1.0% + 4 digits
60Hz -- 500Hz4.000V, 40.00V, 400.0V 1.5% + 4 digits
50Hz -- 500Hz600V2.0% + 4 digits
CMRR>60dB @ DC to 60Hz, Rs=1kÙ
Input Impedance10MÙ, 30pF nominal
DC VoltageGeneral Stats400.0 mV
4.000V, 40.00V, 400.0V
600V
0.3% + 3 digits
0.5% + 3 digits
1.0% + 3 digits
NMRR>50dB @ 50/60Hz
CMRR>120dB @ DC, 50/60Hz, Rs=1kÙ
Input Impedance10MÙ, 30pF nominal (1000MÙ for 400.0mV range)
DC Current (Clamp-on)400.0A 0.0A ~ 400.0A 1.5% + 4 digits
1000A 400A ~ 800A
800A ~ 900A
900A ~ 1000A
1.5% + 4 digits
2.0% + 4 digits
5.0% + 30 digits

Accuracy: Induced error from adjacent current-carrying conductor: < 0.01A/A
Accuracy: ∆ Zero mode must be applied to zero the unit before measurement to ensure accuracy. This is particularly important below 20A.

DC Current (Clamp-on)400.0A 15Hz ~ 40Hz
40Hz ~ 200Hz
200Hz ~ 400Hz @ <50A*
400Hz ~ 1kHz @ <50A*
2.0% + 5 digits
1.5% + 5 digits
1.5% + 5 digits
2.0% + 5 digits
800A 15Hz ~ 40Hz @ 400A ~ 600A
40Hz ~ 100Hz @ 400A ~ 600A
15Hz ~ 60Hz @ 600A ~ 800A
2.0% + 5 digits
1.5% + 4 digits
5.0% + 30 digits

Accuracy: Induced error from adjacent current-carrying conductor: < 0.01A/A
*: Accuracy is specified at <50A in this frequency bandwidth due to limited calibrator output capability for testing.

Audible Continuity TesterOpen Circuit Voltage0.4VDC typical
Range: 400.0Ù; Accuracy1.5% + 6 digits
Audible thresholdbetween 10Ù and 120Ù
Diode TesterOpen Circuit < 1.6 VDC
Voltage Test Current (Typical) 0.4mA
Capacitance500.0nF, 5.000ìF, 50.00ìF,
500.0ìF, 3000ìF3.5% + 6d
Range: Additional 50.00nF range accuracy is not specified
Accuracy: Accuracies with film capacitor or better
Accuracy: Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V