Preen Voltage Regulator APS-33075
5B :
LIMPIEZA :
NEW :
| Model | APS-33010 | APS-33015 | APS-33022 | APS-33030 | APS-33045 | APS-33060 | APS-33075 | |
| Capacity | 10kVA | 15kVA | 22kVA | 30kVA | 45kVA | 60kVA | 75kVA | |
| Input(AC) | Phase | Three Phase | ||||||
| Voltage | 208V/120V , 480V/277Vform 1 | |||||||
| Voltage Range | ± 18% | ± 18% (25% Option) | ||||||
| Frequency | 47Hz ~ 63Hz | |||||||
| Power Factor | 0.95 ~ 1 | |||||||
| Output(AC) | Phase | Three Phase | ||||||
| Voltage | 208V/120V , 480V/277Vform 1 | |||||||
| Frequency | Same as Input Frequency | |||||||
| Power Factor | ± 0.7 ~ 1 | |||||||
| VA Efficiency | ≥ 98% Full Load / No Load energy power consumption ≤ 0.2 | |||||||
| Line Regulation | ± 1% ~ ± 4% | ± 1% ~ ± 2% | ||||||
| Load Regulation | ± 1% ~ ± 4% | ± 1% ~ ± 2% | ||||||
| Total Harmonic Distortion | < 1% (additional waveform distortion | |||||||
| Response Time | ≤ 4ms / Step | |||||||
| Indicator | Voltmeter | Show 0~300VAC for each phase | ||||||
| Ammeter | Show R.S.T. Load's Current | |||||||
| LED | Power abnormal , output voltage overrun (high voltage / low voltage) , auto bypass supply | |||||||
| Protection | Over Range | Power Auto Shut & Led Indicator | ||||||
| Over Load | No Fuse Break | 150% for 15Sec , 130% for 30Sec , 110% for 300Sec | ||||||
| Auto Bypass | Led Indicator & Alarm | |||||||
| Noise Suppressors | High energy surge absorber 、LC Filter、EMI Filter (option) | |||||||
| R.S.T. Phase Failure | Led Indicator (option) & Alarm (option) & Auto shut off (option) | |||||||
| Overload Capacity | 200% for 10 seconds ; 500% for 50ms | |||||||
| Audible Noise | ≤ 50dB | ≤ 55dB | ||||||
| Cooling System | Natural cooling | Fan cooling | ||||||
| Connections | Terminal | |||||||
| Environment | Ambient | 0ºC ~ 40ºC | ||||||
| Humidity | 0~95% (Non-condensing) | |||||||
| Model | APS-33100 | APS-33120 | APS-33150 | APS-331800 | APS-33240 | APS-3300 | |
| Capacity | 100kVA | 120kVA | 150kVA | 180kVA | 240kVA | 300kVA | |
| Input(AC) | Phase | Three Phase | |||||
| Voltage | 208V/120V , 480V/277Vform 1 | ||||||
| Voltage Range | ± 18% (25% Option) | ||||||
| Frequency | 47Hz ~ 63Hz | ||||||
| Power Factor | 0.95 ~ 1 | ||||||
| Output(AC) | Phase | Three Phase | |||||
| Voltage | 208V/120V , 480V/277Vform 1 | ||||||
| Frequency | Same as Input Frequency | ||||||
| Power Factor | ± 0.7 ~ 1 | ||||||
| VA Efficiency | ≥ 98% Full Load / No Load energy power consumption ≤ 0.2 | ||||||
| Line Regulation | ± 1% ~ ± 2% | ||||||
| Load Regulation | ± 1% ~ ± 2% | ||||||
| Total Harmonic Distortion | < 1% (additional waveform distortion | ||||||
| Response Time | ≤ 4ms / Step | ||||||
| Indicator | LCD | Display electrical parameters . stat of the control , memories of history events | |||||
| LED | Power abnormal , output voltage overrun (high voltage / low voltage) , auto bypass supply | ||||||
| Protection | Over Range | Power Auto Shut off (option) & Led Indicator | |||||
| Over Load | 150% for 15Sec , 130% for 30Sec , 110% for 300Sec | ||||||
| Auto Bypass | Led Indicator & Alarm | ||||||
| Noise Suppressors | High energy surge absorber 、LC Filter、EMI Filter (option) | ||||||
| R.S.T. Phase Failure | Led Indicator (option) & Alarm (option) | ||||||
| Overload Capacity | 200% for 10 seconds ; 500% for 50ms | ||||||
| Audible Noise | < 45dB | ||||||
| Cooling System | Air force Fan | ||||||
| Connections | Terminal | Copper Busbar | |||||
| Environment | Ambient | 0ºC ~ 40ºC | |||||
| Humidity | 0~95% (Non-condensing) | ||||||